Applications:
The MAXIMATOR Booster Station will be used for the compression of air or other gases.
Examples:
- Gas transfer
- Cylinder filling
- Leakage tests
- Burst pressure tests
- Pressure testing of equipment
- Test and filling of shock absorbers
- Calibration
Main Benefits:
- Panel mounted instruments ensures easy operation and process control
- Stainless steel components for highest durability
- Multi-purpose useable with its pressure outlet, bleed connection and the additional measuring point
- Panel indicated process chart
Function:
MAXIMATOR compressor stations are driven by air pressure and increase the pressure in the legacy high pressure system according the compressor ratio (see opposite table).
Characteristic feature:
- easy to operate
- compact construction style
- stationary
- pneumatic drive
- no heat, flame or spark risk
Order code:
3230.1275
Circuit diagram no. :
AH 201.251.92
Download:
Data Sheet (PDF format)
Type | DLE- 15-30-GG |
Pressure Ratio: | 1:15: 1:30 |
Outlet Pressure max.: | approx. 600 bar |
Inlet Pressure min.: | 7 bar |
Inlet Pressure max.: | 15 X pL |
Utilities: | Air |
Flow max.: | Depending on application |
Connection Inlet PL / A | BSP 1/2“ / BSP 1/4“ |
Connection Outlet B: | BSP 1/4“ |
Dimension W x T x H: | 930 x 350 x 500 mm |
Weight: | 38 kg |
Air drive pressure | min. 1 bar / max. 10 bar |