Applications:
The MAXIMATOR Hydraulic unit will be used for different pressure tests.
Function:
Basically, Maximator pumps are operating according to the pressure intensifier principle. The outlet pressure is calculated by The transmission ratio between air piston and plunger piston multiplied by the drive pressure. I.e., the static ultimate pressure of the hydraulic can be adjusted by regulation of the supply pressure.
Characteristic feature:
- easy to operate
- compact construction style
- Stationary / mobile
- pneumatic drive
- no heat, flame or spark risk
Order code:
3320.0734
Circuit diagramm no. :
AH 101.655.46
Download:
Data Sheet (PDF Format)
Type: | GX170-01V/C2/SV/T/0-1000(100)/Measuring point/AV2/W/VA |
Pressure ratio: | 1:175 |
Outlet Pressure max.: | 930 bar |
Utilities: | Water |
Flow max.: | |
Connection Inlet PL/PV | BSP 3/4“/BSP 1“ |
Connection Outlet P1/P2/E: | LP9 / LP9 / LP9 |
Dimension W x T x H: | 760 x 600 x 1020 |
Weight: | 114 kg |
Air drive pressure | min. 1 bar / max. 5,5 bar |